Logo

MonoCalc

/

Back Titration Calculator

Chemistry

Reactions and analyte

CaCO₃ in chalk / eggshell
CaCO₃ is insoluble, so it cannot be titrated directly. It dissolves in excess HCl, and the unreacted acid is titrated with NaOH.

① CaCO₃ + 2 HCl → products

② HCl + NaOH → products

M = 100.086 g/mol (parsed)

Method and sample

Titres

UK/IB school convention: 0.10 mL

Back-titres (mL)

#1

Mean 12.600 mL

Untick a reading to exclude it (for example a rough first titre). Empty rows are ignored; the mean of included readings is used.

Result

Purity of CaCO₃

74.86 % w/w

n of CaCO₃

1.870 mmol

HCl reacted

3.740 mmol

HCl left over

1.260 mmol

1.260 mmol NaOH titrated

HCl consumed

74.8 %

of 5.000 mmol

Mass of CaCO₃

187.2 mg

Per gram of sample

748.6 mg/g

Found by difference

① Sample + excess HCl

n_R,total = 5.000 mmol

② CaCO₃ consumes HCl

n_R,reacted = 3.740 mmol

③ Leftover HCl titrated with NaOH

V_T = 12.60 mL, n_T = 1.260 mmol

Sensitivity to the back-titre

Dot: your titre. Dashed line at 50.0 mL: reagent fully left over, no analyte. Shaded band: more than 90 % of the reagent left over, where the result is a small difference of two large numbers and has low confidence.

Step-by-step working

Reaction 1: CaCO₃ + 2 HCl → products

Reaction 2: HCl + NaOH → products

n_R,total = C_R × V_R = 0.2000 mol/L × 25.00 mL = 5.000 mmol HCl

n_T = C_T × V_T = 0.1000 mol/L × 12.60 mL = 1.260 mmol NaOH

n_R,excess = n_T × (r′/t) = 1.260 × 1/1 = 1.260 mmol HCl

n_R,reacted = n_R,total − n_R,excess = 5.000 − 1.260 = 3.740 mmol HCl

n_X = n_R,reacted × (a/r) = 3.740 × 1/2 = 1.870 mmol CaCO₃

m_X = n_X × M_X = 1.870 mmol × 100.086 g/mol = 187.2 mg

% w/w = m_X / m_sample × 100 = 187.2 mg / 250.0 mg × 100 = 74.86 %

About This Tool

Back Titration Calculator – Find an Analyte by Difference

A back titration, also called an indirect titration, measures a substance that cannot be titrated directly. You add a known, excess amount of a reagent, let the analyte use up part of it, and then titrate what is left with a standard solution. The analyte is found by difference. This calculator does the whole chain, from titres to % purity, and shows every step with your numbers so you can check it against your lab notebook.

When a direct titration does not work

Back titrations are used when the analyte is insoluble (calcium carbonate in chalk or eggshell, magnesium hydroxide in antacid tablets), reacts slowly (aspirin hydrolysis, saponification of fats), is volatile (ammonia distilled into acid in the Kjeldahl method), or has no sharp end point with a suitable indicator (aluminium with EDTA). In each case an excess of reagent drives the reaction to completion, and the leftover reagent is easy to titrate.

The two reactions and their ratios

Every back titration involves two balanced equations: the analyte with the reagent, a X + r R → products, and the leftover reagent with the titrant, r′ R + t T → products. Enter the four coefficients and the calculator applies them in the right places. For chalk, CaCO₃ + 2 HCl means each mole of carbonate uses two moles of acid, so a = 1 and r = 2, while HCl + NaOH is 1 : 1.

The standard method

When the reagent concentration is known, the working is:

  • n(R) total = C(R) × V(R)
  • n(R) excess = C(T) × V(T) × (r′ / t) × F, where F is the aliquot factor
  • n(R) reacted = n(R) total − n(R) excess
  • n(X) = n(R) reacted × (a / r), then mass, % w/w or concentration

For example, 0.2500 g of chalk with 25.00 mL of 0.2000 M HCl, back-titrated with 12.60 mL of 0.1000 M NaOH, gives 3.740 mmol of HCl consumed, 1.870 mmol of CaCO₃ and about 74.9 % purity.

The blank method

If the reagent concentration is uncertain, for example NaOH that has absorbed carbon dioxide, run a blank: the same volume of reagent treated the same way but without sample. Then n(R) reacted = C(T) × (V blank − V sample) × (r′ / t) × F, and the reagent concentration cancels out. This is the standard approach for the saponification value of oils, reported in mg KOH per g of fat, and for aspirin assays.

Aliquots and replicate titres

In many practicals the reaction mixture is made up to 250 mL and only 25.00 mL is titrated. The leftover reagent in the whole flask is then ten times what you titrated. Turn on the aliquot option and the factor F = V flask / V aliquot is applied for you. Enter up to six titres, untick a rough trial, and the tool uses the mean of the rest and checks whether they are concordant, within 0.10 mL by the common school convention.

Why the result can be fragile

Because the analyte is a difference of two similar numbers, small errors in either one are magnified. The mole-balance bar shows how much of the reagent was consumed, and the sensitivity chart shows how the result falls as the back-titre rises toward the point where no analyte would be present. The advanced panel propagates burette, pipette, concentration and balance uncertainties in quadrature.

Keep the reagent excess moderate
If almost all of the reagent is left over, the result has a large relative uncertainty. If almost none is left, the reaction may not have gone to completion. Use the Planning tab to choose a reagent volume that gives a comfortable back-titre.

Planning a new experiment

The Planning tab works backwards from an expected sample size and purity. It finds the reagent needed to react with all the analyte, adds your chosen excess, rounds up to a common pipette or burette volume, and predicts the back-titre. It warns you if that titre would overflow the burette or fall below about 5 mL, where reading errors become a large fraction of the volume.

Frequently Asked Questions

Is the Back Titration Calculator free?

Yes, Back Titration Calculator is totally free :)

Can I use the Back Titration Calculator offline?

Yes, you can install the webapp as PWA.

Is it safe to use Back Titration Calculator?

Yes, any data related to Back Titration Calculator only stored in your browser (if storage required). You can simply clear browser cache to clear all the stored data. We do not store any data on server.

How does this back titration calculator work?

It finds the reagent consumed by the analyte by difference: the amount of reagent added minus the amount left over, which is found from the back titration with the titrant and the r′ : t ratio. That difference is converted to moles of analyte with the a : r ratio, then to mass, % purity or concentration.

When should I use the blank method?

Use it when the reagent concentration is not known exactly or drifts, such as NaOH that absorbs CO₂ or ethanolic KOH in a saponification value test. Titrating the same volume of reagent without sample gives the amount added, so only the titrant concentration and the two titres are needed.

What is the aliquot factor?

If the reaction mixture was made up to a volumetric flask and only part of it was titrated, the leftover reagent in the whole flask is the titrated amount times V_flask / V_aliquot. Forgetting this factor is one of the most common back titration mistakes.

Why does the tool warn when most of the reagent was left over?

The analyte is found as the difference of two similar numbers, so their uncertainties stay the same size while the difference shrinks. When more than 90 % of the reagent is left over, the relative uncertainty of the result can be many times that of the titres themselves.

What does concordant mean here?

Titres are flagged as concordant when the included readings lie within 0.10 mL of each other, the usual UK and IB school convention. It is not a universal standard, so you can change the tolerance.

How accurate are the results?

The arithmetic is exact and molar masses come from standard atomic weights, so the result is as good as your measurements and stoichiometry. It cannot detect an incomplete reaction, a side reaction that also consumes reagent, or a wrong indicator end point.