Gravimetric Analysis Calculator

Chemistry
Reagent: AgNO3, precipitating the silver halide
M = 35.450 g/mol
M = 143.320 g/mol
1Cl⟷1AgCl

Key element Cl (the only shared element, chosen automatically): 1 per Cl, 1 per AgCl. Balancing: 1 × 1 = 1 × 1 = 1 Cl atoms, so a : b = 1 : 1.

Gravimetric factor GF = (1 × 35.450) / (1 × 143.320) = 0.2473

0.3 mg is a common lab convention, not a standard; some courses use 0.2 or 0.5 mg.

Trial data

Empty crucible (g)

Tare

Crucible + precipitate (g)

Heating 1

Heating 2

Heating 3

Crucible + precipitate:

Constant mass reached

Last two readings differ by 0.20 mg (tolerance 0.30 mg).

Crucible + precipitate

Shaded band: final reading ± 0.30 mg tolerance.

Results

Precipitate (AgCl)

0.42150 g

Gravimetric factor

0.2473

1 : 1

Mass of Cl

0.1043 g

104.3 mg

Moles of Cl

0.002941 mol

Cl (w/w)

20.85 %

mg per g

208.5

Last two readings differ by 0.20 mg (tolerance 0.30 mg).

Mass breakdown

Sample0.5000 gPrecipitate0.4215 gsame Cl mass: × GFCl 20.85 %matrixCl 0.1043 grest of AgCl0 g0.5000 g

Cl (analyte)

Sample matrix / rest of the weighing form

Step-by-step working

  1. Precipitate mass = 26.4215 g − 26.0000 g = 0.4215 g
  2. M(Cl) = 35.450 g/mol, M(AgCl) = 143.320 g/mol
  3. GF = (1 × 35.450) / (1 × 143.320) = 0.2473
  4. Mass Cl = 0.4215 g × 0.2473 = 0.10426 g (GF kept at full precision)
  5. % Cl = 0.10426 / 0.5000 g × 100 = 20.85 %

About This Tool

Gravimetric Analysis Calculator – From Precipitate Mass to % Analyte

Gravimetric analysis is one of the oldest and most accurate quantitative methods in chemistry: you convert the analyte into a pure solid of known composition, weigh it, and work back to the amount of analyte in the original sample. This calculator handles the arithmetic and the bookkeeping. It derives the gravimetric factor from two chemical formulas, subtracts crucible tares, checks that the precipitate reached constant mass, applies aliquot and blank corrections, and gives replicate statistics with a Dixon Q-test.

Precipitation versus volatilization gravimetry

In precipitation gravimetry a reagent turns the analyte into an insoluble compound: chloride becomes AgCl, sulfate becomes BaSO₄, nickel becomes the red dimethylglyoxime complex. The solid is filtered, washed, dried or ignited and weighed. In volatilization gravimetry you heat the sample and measure what leaves it, such as water of hydration, CO₂ from a carbonate, or moisture in a loss-on-drying test. The Volatilization mode of this tool reports the mass lost and, given a residue and volatile formula, finds x in a formula such as CuSO₄·xH₂O.

What makes a good weighing form

A useful precipitate has very low solubility, so losses in the mother liquor and wash water are negligible. It must have a known, fixed composition after drying or ignition, because the whole calculation rests on its formula. It should form particles large enough to filter easily, and ideally a high molar mass relative to the analyte, which gives a small gravimetric factor and a larger, more precisely weighed mass. Organic precipitants such as 8-hydroxyquinoline and dimethylglyoxime are popular for exactly that reason.

Digestion, coprecipitation and occlusion

Freshly formed precipitates are often fine and impure. Digestion, leaving the solid to stand in the hot mother liquor, lets small crystals dissolve and larger ones grow, giving a purer, more filterable product. Coprecipitation is the carrying down of normally soluble species with the precipitate. It includes surface adsorption, mixed-crystal formation and occlusion, where foreign ions or solvent are trapped inside a growing crystal. Slow precipitation from dilute, hot solution and digestion reduce all of them.

Why heat to constant mass

Drying or ignition must remove all water and convert the solid completely to the weighing form. The only practical proof is to heat, cool in a desiccator, weigh, and repeat until two successive readings agree within a tolerance, often 0.2 to 0.5 mg. Enter each reading in By difference mode and the calculator charts them against the tolerance band, then subtracts the last empty-crucible reading from the last crucible-plus-precipitate reading.

Deriving the gravimetric factor

The factor converts mass of precipitate to mass of analyte:

GF = (a × M analyte) / (b × M precipitate)

The coefficients a and b balance the key element, the one that carries through from analyte to precipitate. Take magnetite, Fe₃O₄, weighed as Fe₂O₃. Each Fe₃O₄ holds 3 Fe and each Fe₂O₃ holds 2, so 2 Fe₃O₄ contain the same 6 Fe atoms as 3 Fe₂O₃. That gives GF = (2 × 231.53) / (3 × 159.69) = 0.9666. The tool finds the shared elements, ignores O and H unless nothing else is shared, and asks you to choose when more than one element could serve.

Worked example
A 0.5000 g sample gives 0.4215 g of AgCl. GF = 35.450 / 143.320 = 0.2473, so the chloride mass is 0.4215 × 0.2473 = 0.10426 g, and the sample contains 0.10426 / 0.5000 × 100 = 20.85 % Cl.

Planning the sample size

A precipitate of a few tenths of a gram is easy to filter and weighs with a small relative error. The Plan mode turns an expected analyte percentage into the sample mass that should give your target precipitate mass, and estimates the weighing uncertainty as √2 × readability / m precipitate, because the precipitate mass comes from two balance readings.

Common sources of error

  • Incomplete precipitation: too little reagent, the wrong pH, or a precipitate that is slightly soluble. Test the filtrate with a drop more reagent.
  • Peptization during washing: washing a colloidal precipitate such as AgCl with pure water can redisperse it so it passes through the filter. Wash with a dilute electrolyte that volatilizes on drying, such as dilute HNO₃.
  • Hygroscopic precipitates pick up water from the air while cooling. Cool in a desiccator and weigh promptly.
  • Incomplete ignition leaves hydrous oxides or partly decomposed oxalates and phosphates, so the solid is not the formula you entered and the result is biased.

Running three or more replicates and looking at the mean, standard deviation and 95 % confidence interval shows how reproducible your technique is. A Q-test flag is a prompt to look for a cause, such as a spilled filtrate or an unignited crucible, before you discard a result.

Frequently Asked Questions

Is the Gravimetric Analysis Calculator free?

Yes, Gravimetric Analysis Calculator is totally free :)

Can I use the Gravimetric Analysis Calculator offline?

Yes, you can install the webapp as PWA.

Is it safe to use Gravimetric Analysis Calculator?

Yes, any data related to Gravimetric Analysis Calculator only stored in your browser (if storage required). You can simply clear browser cache to clear all the stored data. We do not store any data on server.

How does this gravimetric analysis calculator work?

It parses the analyte and weighing-form formulas, balances the key element they share to find the ratio a : b, and computes the gravimetric factor GF = (a × M analyte) / (b × M precipitate). The precipitate mass times GF gives the analyte mass, which is then related back to the sample as % w/w or a concentration.

What is the gravimetric factor for chloride weighed as AgCl?

GF = M(Cl) / M(AgCl) = 35.450 / 143.320 = 0.2473, so every gram of AgCl contains 0.2473 g of chloride. For iron weighed as Fe₂O₃ the factor is 2 × 55.845 / 159.687 = 0.6994.

Can I type ions such as SO4^2- or Cl-?

Yes. Charges written with superscripts, a caret (SO4^2-), a space (SO4 2-) or a bare sign (Cl-, NH4+) are removed, since charge does not change the mass. A charge glued to the subscript, such as SO42- or Fe3+, is ambiguous and is rejected with a prompt to rewrite it.

What counts as constant mass?

The calculator treats the precipitate as at constant mass when the last two weighings after successive heating cycles agree within the tolerance you set. The default of 0.3 mg is a common teaching-lab convention, not a formal standard, and some courses use 0.2 or 0.5 mg.

Does the calculator reject outliers automatically?

No. The Dixon Q-test only flags the most extreme replicate at 90 % or 95 % confidence using Rorabacher's critical values. You decide whether to exclude it, and the mean, standard deviation and confidence interval are recomputed when you do.

How accurate are the results?

The arithmetic uses IUPAC standard atomic weights at full precision, so the answer is as good as your weighings and chemistry. It cannot correct for incomplete precipitation, coprecipitation, a weighing form of uncertain composition or incomplete ignition.