Logo

MonoCalc

/

Nernst Equation Calculator

Chemistry

E = E° − (RT/nF)·ln Q. Solve for any variable, work out a concentration cell, find membrane equilibrium potentials (E_K, E_Na, E_Cl, E_Ca), or see how a couple shifts with pH.

Presets

Reaction

Need E°cell from two half-reactions first? Use the Standard Cell Potential Calculator, then enter it here as a custom reaction or with Q directly.

Cu²⁺(aq) + 2e⁻ → Cu(s)

E° = +0.3419 V vs SHE · n = 2 · dE°/dT = 0.0107 mV/K

Concentrations and pressures

[Cu²⁺]

Cu(s): activity = 1

Solve for

E° and n come from the table here. Switch to a custom reaction or Q directly to solve for them.

E vs SHE
+0.2827 V

E° at T

+0.3419 V

+0.3419 V at 25 °C

Q

100.0

log₁₀Q = 2.0000

n

2

T

25.00 °C

A half-cell potential, measured against SHE. ΔG needs a complete cell.

Shift from standard: ΔE = E − E° = −59.16 mV. Q is 10², so E moves by 2.00 × 29.58 mV = −59.16 mV from E°.

Slope at 25.00 °C: s = 2.303RT/F = 59.16 mV per decade; RT/F = 25.69 mV; s/n = 29.58 mV per decade

E = E° − (RT/nF)·ln Q = +0.3419 − (8.314462618 × 298.15 / (2 × 96485.33212))·4.6052 = +0.2827 V

E = E° − (s/n)·log₁₀Q = +0.3419 − (0.0591593 / 2)·2.0000 = +0.2827 V

Cu(s): pure phase, activity = 1.

Ideal behaviour assumed: concentrations (M) and pressures (bar) stand in for activities. Above about 0.01 M, activity coefficients matter. See the Ionic Strength Calculator.

E (V vs SHE) against log₁₀Q · slope −29.58 mV per decade (n = 2, 25.0 °C)

log₁₀Q →

About This Tool

Nernst Equation Calculator – Potentials Away from Standard Conditions

Tabulated standard reduction potentials assume every dissolved species is at 1 M and every gas at 1 bar. Real solutions almost never are. The Nernst equation corrects E° for the actual concentrations, pressures and temperature. This calculator solves it for any one unknown, handles concentration cells, finds membrane equilibrium potentials such as E_K and E_Na, and shows how a couple involving H⁺ shifts with pH. If you first need E°cell from two half-reactions, use the Standard Cell Potential Calculator.

Where the equation comes from

The free-energy change of a reaction depends on how far it is from equilibrium through the reaction quotient Q. An electrochemical cell turns that free energy into electrical work, so ΔG and E are tied by the Faraday constant. Substituting one relation into the other gives the Nernst equation:

ΔG = ΔG° + RT·ln Q
ΔG = −nFE   and   ΔG° = −nFE°
−nFE = −nFE° + RT·ln Q
E = E° − (RT/nF)·ln Q = E° − (s/n)·log₁₀Q

Q is products over reactants, each raised to its stoichiometric coefficient. Pure solids and liquids count as 1. For a half-reaction written as a reduction, Q is the reduced side over the oxidised side, with the electrons left out.

Why 59.16 mV per decade

Converting the natural logarithm to base 10 pulls out a factor of ln 10. The constant in front, s = 2.303RT/F, is the Nernst slope:

s = RT·ln 10 / F
  = 8.314462618 × 298.15 × 2.302585 / 96485.33212
  = 0.05916 V = 59.16 mV per decade (25 °C)
  = 61.54 mV per decade (37 °C)

Divide s by n for the shift per tenfold change in Q. A two-electron couple moves 29.58 mV per decade at 25 °C, and a five-electron couple 11.83 mV. The calculator always shows s, RT/F and s/n at your temperature, and draws E against log₁₀Q as a straight line of slope −s/n through E° at Q = 1.

The log term is per decade
Tenfold changes move E by only s/n. Doubling a concentration changes the potential by just 0.301 × s/n, under 9 mV for a two-electron couple at 25 °C.

Worked example: copper at 0.010 M

For Cu²⁺(aq) + 2e⁻ → Cu(s), E° = +0.3419 V and Q = 1/[Cu²⁺] = 1/0.010 = 100, so log₁₀Q = 2. Then E = 0.3419 − (0.05916/2) × 2 = 0.2827 V. Diluting the copper ions a hundredfold lowers the electrode potential by 59 mV. Solve the same equation backwards and a measured voltage gives an unknown concentration. This is how ion-selective electrodes and pH meters work.

Concentration cells

Put the same couple on both sides and E° cancels. The only driving force left is the concentration difference: E = (s/n)·log₁₀(c_concentrated / c_dilute). Copper at 0.0010 M against 1.0 M gives 0.0887 V. The dilute side is the anode, where copper dissolves, until both sides are equal. A hydrogen cell at two pressures runs the opposite way: the high-pressure side is the anode.

Membrane potentials in biology

Cells hold K⁺ high inside and Na⁺ high outside. For each ion, the Nernst equation gives the voltage at which its concentration gradient is exactly balanced: E_ion = (RT/zF)·ln([out]/[in]), measured inside relative to outside. With typical neuron values at 37 °C, E_K is about −89 mV and E_Na about +67 mV. The resting membrane is far more permeable to K⁺ than to Na⁺, so the resting potential sits near E_K, at roughly −70 mV. The difference V_m − E_ion is the driving force that pushes each ion in or out when its channels open.

pH dependence and the water window

When H⁺ takes part in a half-reaction, its activity sits in Q, and E falls by (m/n) × 59.16 mV for every pH unit at 25 °C. O₂/H₂O drops 59.16 mV per pH, and MnO₄⁻/Mn²⁺ 94.65 mV. The O₂/H₂O and H⁺/H₂ lines bound the region where water itself is stable. Couples above the top line can oxidise water, and couples below the bottom line can reduce it. The E vs pH mode draws these lines and marks where two couples cross. It is not a full Pourbaix diagram, which would also need solubility and acid–base boundaries.

Activity, not concentration
The Nernst equation is exact for activities. Using molar concentrations and bar pressures is accurate only for dilute, near-ideal solutions. Above about 0.01 M, activity coefficients fall well below 1, and a computed potential can be off by several millivolts. Use the Ionic Strength Calculator to judge how far from ideal a solution is.

Frequently Asked Questions

Is the Nernst Equation Calculator free?

Yes, Nernst Equation Calculator is totally free :)

Can I use the Nernst Equation Calculator offline?

Yes, you can install the webapp as PWA.

Is it safe to use Nernst Equation Calculator?

Yes, any data related to Nernst Equation Calculator only stored in your browser (if storage required). You can simply clear browser cache to clear all the stored data. We do not store any data on server.

How does this Nernst equation calculator work?

It uses E = E° − (RT/nF)·ln Q, written as E = E° − (s/n)·log₁₀Q with s = 2.303RT/F. Pick a half-reaction from the table, type a custom reaction, or enter Q directly, then choose which variable to solve for; the tool rearranges the equation and shows every substituted step.

Why does the potential change so little when the concentration changes?

The concentration enters through a logarithm. At 25 °C each tenfold change in Q moves E by only 59.16 mV divided by n, so even a hundredfold dilution of Cu²⁺ (n = 2) shifts the copper electrode by about 59 mV.

Which way does a concentration cell run?

In an ion concentration cell the dilute side is the anode: the metal dissolves there and ions plate out on the concentrated side until the two concentrations are equal. In a hydrogen pressure cell it is the other way round: the high-pressure H₂ side is the anode.

Is the Nernst potential the same as the resting membrane potential?

No. The Nernst potential is the equilibrium voltage for one ion on its own. The resting potential of a real cell depends on several permeable ions and their permeabilities, which the Goldman–Hodgkin–Katz equation describes; it sits close to E_K because the resting membrane is mostly permeable to K⁺.

Why isn't E° simply rescaled with RT/nF at another temperature?

E° itself changes with temperature through the reaction entropy: dE°/dT = ΔS°/(nF). The RT/nF term only covers how the concentration term scales. Where the table has dE°/dT, the tool can correct E° linearly; otherwise it keeps the 25 °C value and says so.

Can I use concentrations instead of activities?

For dilute solutions, yes; that is what the calculator assumes. Above roughly 0.01 M, ion interactions make the activity noticeably smaller than the concentration, so the result becomes an estimate. The Ionic Strength Calculator helps judge how far from ideal a solution is.