RLC Circuit Impedance Calculator – Complex Z, Phase and Power Factor
A resistor, an inductor and a capacitor wired together form the most common AC network in electronics, from mains motor loads to radio tuning circuits. This RLC impedance calculator tells you what that network looks like to the source at one frequency: the complex impedance in rectangular and polar form, the phase angle, the power factor, and, if you enter a source voltage, the voltage and current at every element along with real, reactive and apparent power. Four visuals do most of the explaining: a live schematic, an impedance triangle, a phasor diagram and a frequency sweep.
Why impedance is a complex number
A resistor opposes current in phase with the voltage. An inductor and a capacitor store energy instead, and their opposition, called reactance, shifts the current by a quarter cycle. Inductive reactance X_L = 2πfL rises with frequency and makes current lag; capacitive reactance X_C = 1/(2πfC) falls with frequency and makes current lead. Writing impedance as Z = R + jX keeps both effects in one number: the real part dissipates power, the imaginary part stores it, and |Z| = √(R² + X²) with φ = atan2(X, R) give the magnitude and angle. This tool uses the usual sign convention: positive reactance and positive phase mean an inductive load.
Series versus parallel intuition
In a series RLC circuit impedances add, so Z = R + j(X_L − X_C). At very low frequency the capacitor is nearly an open circuit and blocks everything; at very high frequency the inductor does. In between, at f₀ = 1/(2π√(LC)), the two reactances cancel and only R is left, so current peaks. In a parallel RLC circuit admittances add instead: Y = 1/R + j(ωC − 1/(ωL)). Now the extremes are shorts: the inductor shorts the source at low frequency and the capacitor at high frequency, and at f₀ the circuit looks like R alone, which is a maximum of impedance rather than a minimum.
The element switches let one tool cover RL, RC, LC and single-element circuits. In series a disabled part becomes a short; in parallel it becomes an open branch. Try the RC low-pass preset: at 1 kHz with 1.59 kΩ and 100 nF the reactance almost equals R, so the phase is about −45°, which is the familiar filter corner.
The impedance triangle and the phasor picture
The impedance triangle plots R along the real axis, the net reactance vertically, and Z as the hypotenuse. The axes are drawn to equal scale, so the angle you see is the true phase. For a parallel circuit the natural picture is the admittance triangle of G, B and |Y|, which you can toggle to. The phasor diagram shows the same story with voltages or currents: in a series loop the shared current is the reference, V_R lies along it, V_L points up and V_C points down, and their tip-to-tail sum is the source voltage. Near resonance V_L and V_C can each be many times the supply because they almost cancel, which is why the tool warns about resonant voltage magnification. A parallel circuit does the same with circulating current.
Leading and lagging power factor
Power factor is PF = cos φ = Re(Z)/|Z|. It is the share of the apparent power S = V·I that does real work, P = I²·Re(Z). The rest is reactive power Q = I²·Im(Z), which sloshes back and forth each cycle. An inductive load such as a motor has a lagging power factor; a capacitive load has a leading one. The RL motor preset (8 Ω, 30 mH at 50 Hz) gives a lagging PF of about 0.65, which is why industrial sites add capacitors for power factor correction.
Why a lossy tank has three resonant frequencies
A real inductor has winding resistance, so a practical tank circuit is (R + jωL) ∥ C, not an ideal parallel LC. Once R is in the coil branch, three frequencies that coincide in the ideal case drift apart:
- the ideal f₀ =
1/(2π√(LC)); - the unity-power-factor frequency, where
ω² = 1/(LC) − (R/L)²and the impedance is purely resistive atZ_dyn = L/(RC); - the maximum-|Z| frequency, where the magnitude actually peaks.
For the 5 Ω, 100 µH, 1 nF AM tank they differ by only about 63 Hz at 503 kHz, but for a low-Q coil the gap becomes large. Once R reaches √(L/C) there is no unity-PF point at all.
X_L = 62.83 Ω, X_C = 159.15 Ω, so Z = 10 − j96.32 Ω = 96.84 Ω ∠ −84.07°. With 10 V applied the current is 103.3 mA and the capacitor sees 16.4 V, more than the source.Using the frequency sweep
The sweep plots |Z| on a log scale and the phase underneath, centred on f₀ with an adjustable span. Markers show the operating frequency and the resonant points, and clicking the chart moves the operating frequency. It turns a single figure such as “Z = 96.8 Ω” into context: the series example sits on the capacitive slope, heading for a minimum at 1.59 kHz. For full resonance design, including Q, bandwidth and tolerance windows, use the dedicated LC resonance calculator.